This handheld live fibre identifier uses macro bending to detect light in a fibre without cutting it or interrupting traffic. It shows whether the fibre is live or dark, the signal direction and the relative core power, and identifies 270Hz, 1kHz and 2kHz test tones with an audible warning, over a wavelength response of 800nm to 1700nm. Order it without a VFL, or with a built-in 10mW, 650nm visual fault locator on an FC/PC port.
Features and Benefits
- Non-destructive macro-bend detection - find the working fibre without breaking the link.
- Left and right direction indicators - confirm which way traffic is flowing before you cut or re-route.
- 270Hz, 1kHz and 2kHz tone identification with audible warning - match the fibre carrying your test tone.
- Relative core power on a red LED segment readout - easy to read in a dim cabinet.
- One clamp for 250µm, 900µm, 2.5mm and 3mm fibre - no adaptor changes between sizes.
- Low battery indication - warns you before the batteries run flat.
- Optional 10mW VFL (650nm ±10nm, FC/PC) - visible red light for fault finding from the same tool.
Applications
- Identifying live fibres at ODFs, splice closures and patch panels.
- Confirming traffic direction before maintenance or re-routing.
- Tone tracing fibres during FTTH installs and moves.
- Visual fault finding on patch leads and short runs (VFL version).
Note: The 2 x AA 1.5V alkaline batteries are removed before shipping, so fit new ones on arrival. On the VFL version, never look into the laser output or a live fibre end.
Wavelength response: 800nm to 1700nm (data sheet; listing title states 750 to 1700nm). Identified signal tones: 270Hz, 1kHz, 2kHz. Modulated signal identification: Yes. Power measurement: Relative core power. Signal direction: Left and right indicators. Detector: 1mm InGaAs. Fibre sizes: 250µm, 900µm, 2.5mm and 3mm. Insertion loss when clamped: 1.0dB (250µm), 2.0dB (900µm), 3.0dB (3mm). Minimum detection power at 1550nm: -35dBm (250µm and 900µm), -30dBm (3mm). Minimum detection power at 1310nm: -30dBm (250µm and 900µm), -25dBm (3mm). Fibre modes: SM and MM. Tone alert: Audible warning. Low power monitoring: Yes. VFL (VFL version only): 10mW, 650nm ±10nm, FC/PC port. Size: 230 x 43 x 36mm. Weight: 200g. Power supply: 2 x AA 1.5V alkaline batteries, removed for shipping. Operating temperature: -10°C to +50°C. Storage temperature: -20°C to +70°C. Display: Red LED segment readout. Controls: ON/OFF and GLINT buttons. Versions: Without VFL, or with 10mW VFL. Q: What is a live fibre identifier used for? A: It tells you whether a fibre is carrying light, which way the signal is going and whether a test tone is present, so you can pick the right fibre before cutting or re-routing.. Q: Does clamping the fibre interrupt the signal? A: No. It works by macro bending and does not interrupt communications, but it adds a small insertion loss: 1.0dB on 250µm fibre, 2.0dB on 900µm and 3.0dB on 3mm.. Q: Which test tones does it identify? A: 270Hz, 1kHz and 2kHz, with an audible warning when a tone is found.. Q: What is the weakest signal it can detect? A: At 1550nm it detects down to -35dBm on 250µm and 900µm fibre and -30dBm on 3mm; at 1310nm the figures are -30dBm and -25dBm.. Q: What is the difference between the two versions? A: Both identify live fibre. The VFL version adds a 10mW, 650nm visual fault locator on an FC/PC port for finding breaks and bad connectors..