This multi-channel thermocouple thermometer lets you check four temperature points at the same time. It's a digital data logger made for K, J, or T-type thermocouple probes. It gives accurate readings for industrial testing, checks, and quality control in one device. Features and Benefits
- Four Simultaneous Channels - It takes up to four thermocouple probes. This lets it check and show four temperatures at once. This helps when comparing input and output temperatures on HVAC systems.
- Large Data Logging Memory - It saves up to 5,000 groups of readings inside. You can set it to record at certain times. This captures temperature changes over hours or days.
- USB Data Export - Connect the device to a computer with the included USB cable. You can download all saved data as a CSV or TXT file. This makes it easy to look at in a spreadsheet.
- Adjustable High/Low Alarms - Set a custom temperature range for each channel. If a reading goes above or below your limits, a loud beep and flashing screen will warn you. Applications
- HVAC and Refrigeration - For finding system problems. It measures temperatures at the condenser, evaporator, and air vents all at once.
- Industrial and Manufacturing - To check temperatures in ovens, motors, and chemical processes. This makes sure they work within safe and good ranges.
- Lab and Scientific Research - For experiments that need accurate, multi-point temperature tracking. It can also save and export data for reports.
What It Is
This is a 4-Channel Thermocouple Data Logger, designed for recording temperature data. It has a significant data logging capacity, able to store 5000 groups of readings. The unit comes with a battery included and features a USB connection for data export. It is compatible with K, J, and T type thermocouples, making it versatile for various temperature measurement tasks. This device focuses solely on temperature measurement.
Key Uses & Applications
This data logger is ideal for monitoring temperature over time in multiple locations simultaneously. Its 4 channels allow for comparative analysis or comprehensive recording of different points. Typical applications include HVAC system diagnostics, industrial process control, and environmental monitoring. The ability to export data via USB makes it suitable for detailed analysis and reporting in engineering and maintenance roles.
How to Choose
When selecting a thermocouple data logger, consider the number of channels required for your application; this model offers 4. Ensure compatibility with your existing thermocouples; this unit supports K, J, and T types. Check the data logging capacity needed for your projects; this device records 5000 groups. For water heater maintenance, a thermocouple is a safety device; if a water heater isn't staying lit, the thermocouple may need cleaning or replacing. Similarly, for a gas fireplace, if the pilot light won't stay lit, the thermocouple is often the cause.
Grit / Spec Guide
This data logger supports K, J, and T type thermocouples. The unit has 4 channels, allowing for simultaneous measurement with four separate probes. Its data logging capacity is 5000 groups. Data export is facilitated via USB. It is designed specifically for temperature measurement. There is no semi-finished product status; it is a complete unit. A battery is included for immediate use.
Care & Safety
To maintain the accuracy and longevity of your thermocouple data logger, ensure the lead and connector are free from damage. When handling the probe, avoid bending or kinking the lead excessively. For a water heater thermocouple, cleaning involves carefully wiping away soot or mineral deposits with fine-grade sandpaper or emery cloth. For gas fireplace thermocouples, similar cleaning can be effective. Always disconnect power or gas before attempting maintenance. If a thermocouple is faulty, it typically needs replacement rather than repair.
Data Logging Capacity: 5000 Groups. Channels: 4. Data Export: USB. Measurement Type: Temperature. Thermocouple Type: K, J, T. Data Logging Capacity: 5000 groups of records. Measurement Range (J-Type): -210°C to 1200°C (-346°F to 2192°F). Measurement Range (K-Type): -200°C to 1372°C (-328°F to 2501°F). Measurement Range (T-Type): -200°C to 400°C (-328°F to 752°F). Data Export Interface: USB. Thermocouple Types Supported: K, J, T. Operating Temperature: 0°C to 50°C. Storage Temperature: -10°C to 60°C. Accuracy: ±0.1% reading + 0.5°C (typical). Display: Digital LCD with Backlight. Number of Channels: 4. Product Name: 4-Channel K/J/T Type Thermocouple Thermometer Digital Data Logger. Product Status: Finished Product. Resolution: 0.1°C / 0.1°F. Sampling Rate: Adjustable (e.g., 1 second to 24 hours). Q: How many temperature inputs does this thermometer have? A: This is a 4-channel data logger. It allows you to connect and simultaneously monitor temperatures from four separate probes.. Q: What type of thermocouple probes are compatible with this device? A: This thermometer works with K-type, J-type, and T-type thermocouple probes. The device automatically recognizes the type of probe you plug into each of the four channels.. Q: How much data can it store and how do I export it? A: The internal memory can record up to 5,000 groups of temperature readings. You can transfer the saved data to a computer as a file using the included USB cable.. Q: What kind of warranty is offered with this temperature tester? A: It includes a one-year warranty that covers any failures due to manufacturing defects. Please note this doesn't cover damage from accidents, like dropping the unit or exposing it to moisture.. Q: What's the main benefit of this over just using four separate thermometers? A: This data logger records all four temperature inputs into a single, time-stamped file, which is essential for comparing data from an industrial process or scientific experiment. It also has built-in functions to display minimum, maximum, and average temperatures for your analysis..