The Schneider Electric IPRD1 T1 4P Surge Protector is a Class I device engineered for robust primary protection in demanding electrical environments. It offers a high 50 kA (8/20 µs) discharge capacity per phase and a low 1.5 kV voltage protection level (Up), ensuring superior equipment safety by diverting major surge currents away from sensitive installations. Features and Benefits
- Class I Surge Protection Device (SPD) - Provides primary protection against direct lightning strikes and high-energy surges, serving as the first line of defense for your electrical system.
- 50 kA per phase discharge capacity (8/20 µs) - Handles extremely high surge currents, ensuring long-term reliability and durability under severe electrical stress.
- Low voltage protection level (Up) of 1.5 kV - Limits the voltage let-through to connected equipment, minimizing the risk of damage to sensitive electronics and machinery.
- 4-pole design (L1, L2, L3, N) - Offers comprehensive protection for three-phase electrical systems, safeguarding all active conductors and the neutral line.
- Thermal and short-circuit protection - Integrated safety mechanisms disconnect the device in case of overload, preventing fire hazards and ensuring safe failure mode.
- Remote signaling contact - Allows for easy integration into building management systems for remote monitoring of the SPD's status and maintenance alerts. Applications
- Industrial and Commercial Main Distribution Boards - Install at the service entrance of factories, data centers, and commercial buildings to protect the entire electrical infrastructure from external surges.
- Renewable Energy Installations - Safeguard inverters and control systems in solar PV or wind power setups, which are highly exposed to lightning and switching surges.
- Agricultural and Water Treatment Facilities - Protect motors, pumps, and automation equipment in remote locations prone to lightning strikes and unstable grid conditions.
- Telecommunications Infrastructure - Ensure the reliability of base stations and communication hubs by mitigating surges induced on power lines. Note
This device is designed for installation by a qualified electrician in accordance with local regulations and standards. Regular inspection is recommended as part of a comprehensive surge protection plan.
Dimensions (H x W x D): 90 mm x 72 mm x 65 mm. Weight: 0.35 kg. Nominal Voltage (Un): 230/400V AC. Maximum Continuous Operating Voltage (Uc): 320V AC. Voltage Protection Level (Up): ≤ 1.5 kV. Overvoltage Category: IV. Storage Temperature Range: -40°C to +85°C. Conductor Cross-Section: 1.5 mm² to 35 mm². Electrical Connection: Screw Clamp. Follow Current Interrupting Rating: 25 kA. Ingress Protection (IP): IP20. Maximum Discharge Current (Imax): 40 kA (8/20 µs). Mounting: DIN Rail (35 mm). Nominal Discharge Current (In): 20 kA (8/20 µs). Number of Poles: 4. Operating Temperature Range: -40°C to +80°C. Pollution Degree: 3. Product Name: IPRD1 T1 4P Surge Protector. Product Type: Class I Surge Protective Device (SPD). Relative Humidity: 5% to 95% (non-condensing). Remote Signaling Contact: 1 NO/1 NC. Response Time: < 100 ns. Short-Circuit Current Rating (SCCR): 25 kA. Status Indication: Visual (Green/Red). Thermal Protection: Yes. Torque: 2.5 N·m. Housing Material: Thermoplastic (UL94 V-0). Maximum Continuous Operating Voltage (Uc): 320/350V AC. Nominal Voltage (Un): 230/400V AC. Voltage Protection Level (Up): ≤ 2.5 kV. Operating Temperature Range: -40°C to +80°C. Follow Current Interrupting Rating (Ifi): 5 kA. Short-Circuit Current Rating (Isc): 25 kA. Standards Compliance: IEC 61643-11, EN 61643-11. Maximum Discharge Current (Imax): 50 kA (8/20 µs). Mounting: DIN Rail Mounting (35mm). Nominal Discharge Current (In): 12.5 kA (8/20 µs). Product Type: Class I Surge Protection Device (SPD). Protection Mode: 4P (Line-Line & Line-Earth Protection). Response Time: < 100 ns. Status Indication: Visual (green/red) and remote signaling contact. Thermal Protection: Integrated disconnector with remote signaling contact. Q: What are the key specifications and dimensions of the Schneider Electric IPRD1 T1 4P Surge Protector? A: The Schneider Electric IPRD1 T1 is a Class I, 4-pole surge protection device designed for robust electrical installations. While specific dimensions are not provided, it is engineered for standard DIN rail mounting in distribution boards, ensuring compatibility with professional electrical setups.. Q: How durable is the Schneider Electric IPRD1 T1 surge protector for long-term use? A: As a Class I surge protector from Schneider Electric, the IPRD1 T1 is built to withstand high-energy direct lightning strikes, ensuring long-term durability. Its design prioritizes reliable protection and stable performance in demanding electrical environments.. Q: Is the Schneider Electric IPRD1 T1 4P surge protector compatible with my existing electrical panel? A: Yes, the Schneider Electric IPRD1 T1 is designed for standard DIN rail mounting, making it compatible with most modern electrical distribution boards and panels. It is specifically intended for use as a primary point of surge protection in three-phase electrical systems.. Q: Does the Schneider Electric IPRD1 T1 surge protector come with a warranty or performance guarantee? A: Schneider Electric products typically come with a manufacturer's warranty that covers defects in materials and workmanship. For specific warranty details and duration for the IPRD1 T1 model, it is best to consult the official product documentation or the supplier.. Q: Is the Schneider Electric IPRD1 T1 a good value compared to other surge protection devices? A: Yes, the Schneider Electric IPRD1 T1 offers excellent value for professionals and serious DIYers seeking reliable, high-performance surge protection without the highest premium brand pricing. It delivers the essential robust protection of a Class I device from a trusted name in electrical equipment..