The XKC-Y25 is a sensor that detects liquid levels without touching the liquid. It uses capacitance to sense water through container walls. This sensor works like a simple liquid level switch. It never touches the fluid, which is good for projects needing a clean, dependable water detection sensor. Features and Benefits
- No contact needed - It attaches to the outside of a tank. This prevents liquid contamination and corrosion.
- Sensitivity adjusts - A small screw lets you fine-tune detection. It works for different non-metallic materials and thicknesses.
- NPN signal output - It gives a simple high/low signal. This is easy to connect with microcontrollers like Arduino or PLCs.
- Remembers level setting - It keeps your setting after a power cycle. You don't need to reset it. Applications
- Home water tanks - You can automate a pump. This helps maintain water levels in a storage tank.
- Aquarium projects - Build an auto top-off system. You won't need to drill into your glass or acrylic tank.
- DIY electronics - Make a simple alert. It signals when a container is full or empty.
What It Is
This is a Y25-V 12V digital output capacitive liquid level sensor designed for non-contact detection. It operates within a voltage range of 5-24V DC. As a proximity sensor, it detects the presence or absence of liquid without direct physical contact, making it suitable for applications where direct contact could cause contamination or damage. The sensor functions based on capacitance theory, meaning it measures changes in electrical capacitance caused by the presence of a liquid. This electronics module provides a digital output, indicating a clear on/off state for liquid level detection.
Key Uses & Applications
This non-contact liquid level sensor is ideal for various industrial and automation applications where reliable liquid level monitoring is crucial. Its 5-24V DC voltage range makes it compatible with many existing control systems. Common uses include monitoring fluid levels in tanks, reservoirs, and pipes without needing to drill into the container, preventing leaks or contamination. As a proximity sensor, it is particularly useful in environments where hygiene is paramount. It can be integrated into control systems to trigger pumps, alarms, or shut-off valves when a specific liquid level is reached.
How to Choose
When selecting a sensor for liquid level detection, consider the required voltage, which for this model is 5-24V DC. The non-contact detection method is crucial for applications where the sensor cannot directly touch the liquid. Ensure the digital output type is compatible with your control system. For testing a proximity sensor like this, apply the specified voltage (5-24V DC) and observe the digital output change when liquid is introduced or removed from the detection zone. While this is a capacitive sensor, other types of proximity sensors exist, such as optical sensors, which may be more suitable for different materials or distances beyond 5 cm.
Voltage: 5-24V DC. Detection Method: Non-contact. Output Type: Digital. Sensor Type: Capacitive Liquid Level Sensor. Theory: Capacitance Sensor. Cable Length: 1.5 meters. Detection Thickness (Non-metallic container): 0 mm to 20 mm. Operating Voltage: 5V DC to 24V DC. Humidity Range: 5% to 95% RH (non-condensing). Output Type: NPN/PNP (configurable). Operating Temperature: -20°C to 85°C. Storage Temperature: -30°C to 100°C. Protection Rating: IP67. Current Consumption: 5 mA (typical). Detection Principle: Non-contact capacitive sensing. Mounting Method: Adhesive or bracket. Response Time: 500 ms. Theory: Capacitance Sensor. Q: What's the maximum wall thickness this sensor can detect a liquid through? A: It can reliably detect liquid levels through non-metallic container walls up to 20mm thick. The sensitivity is also adjustable, which lets you fine-tune it for the specific material and thickness of your tank.. Q: How well does this sensor handle dusty or wet conditions? A: It's built to withstand tough environments and has an IP67 waterproof rating. This means it's fully protected from dust ingress and can even be submerged in water up to 1 meter deep for about 30 minutes without issue.. Q: Will this work if I have a stainless steel or aluminum tank? A: No, this model is designed specifically for non-metallic containers. It works great with plastic, glass, ceramic, and other similar materials, but it cannot detect liquids through metal.. Q: What kind of warranty comes with the sensor? A: It includes a 12-month manufacturer's warranty against any defects in materials or workmanship. If you have any problems within that year, just contact us and we'll help with a replacement or support.. Q: Why would I use this capacitive sensor instead of a standard float switch? A: This capacitive sensor is non-contact, so it mounts on the outside of your tank. This means there are no moving parts to get stuck or wear out, and the sensor never touches the liquid, preventing contamination..