Looking for jobsite lighting & temporary power solutions to keep your commercial construction projects running safely and on schedule? Compel distributes a complete range of industrial-grade illumination and power generation equipment engineered for demanding worksites. Our inventory spans high-output mobile light towers, adjustable LED bay fixtures, and silent diesel generators, alongside portable inverter units and emergency battery backup systems.

We serve electrical contractors, site managers, and industrial facility operators who require dependable field power and high-visibility lighting. By sourcing from Compel, you secure equipment built to withstand harsh physical environments while meeting strict electrical safety requirements. We supply globally compliant units with international voltage configurations, ensuring your crews have the reliable power and clear visibility needed to maintain productivity.

9 products in Jobsite Lighting & Temporary Power

Matching Generator Power Output and Fuel Type to Your Site

Contractors must balance portability against continuous power needs when choosing generators. For voltage-sensitive electronic tools, inverter technology provides clean power with stable 120V AC output and low noise. Heavy-duty construction sites often require diesel-powered generators that deliver 220V to 400V multi-phase outputs for running heavy machinery over extended runtimes.

Consider the starting wattage of your tools alongside their running wattage. A generator with a 5600W rated output and a 7000W maximum output provides the necessary surge capacity for electric motors to turn over without tripping the breaker.

  • Gasoline Inverters: Best for portable, low-noise 120V applications up to 4000W.
  • Heavy-Duty Diesel: Suitable for continuous 220V, 240V, or 400V requirements and high-draw equipment.
  • Receptacle Types: Ensure compatibility with standard 5-20R (120V 20A) or L14-30R twist-lock outlets for distribution panels.

Specifying Industrial Jobsite and Workshop Lighting

Temporary and permanent industrial lighting must handle wide input voltage ranges, often from 100V to 277V AC, to accommodate fluctuating site power. High bay UFO fixtures ranging from 50W to 600W provide wide-area illumination for warehouses and workshops. For outdoor sites, mobile light towers with integrated diesel generators and high-output LED floods offer standalone illumination without relying on grid power.

  • Input Voltage: Choose wide-range AC drivers (100-277V or 85-265V) to survive voltage drops on long cable runs.
  • Color Temperature: Opt for 5000K to 6500K cool white light to maximize visibility and reduce worker eye strain.
  • Materials: Select aluminum alloy housings with polycarbonate diffusers for impact resistance in active work zones.

Evaluating Battery Backup System Specifications

When continuous operation of critical equipment is non-negotiable, select backup systems with rapid transfer times. Systems designed for critical pumps or controls should feature an automatic transfer time of less than 20 milliseconds to prevent system resets. Use pure sine wave inverters to protect sensitive control boards from electrical damage during utility failures.

  • Transfer Speed: Keep transfer times under 20ms for reliable backup transitions.
  • Battery Type: Utilize deep-cycle AGM or Gel lead-acid batteries for reliable long-term standby power.

Buying guide

Choosing Jobsite Lighting & Temporary Power

How do I calculate the generator capacity needed for my site tools?
Add the continuous running wattage of all connected tools, then add the highest starting wattage among those tools. For example, a 5600W rated generator with a 7000W maximum output can handle multiple small loads plus the high inrush current of a single large motor. Always allow a twenty percent safety margin to prevent generator overload.
What outlet configurations are standard on your portable industrial generators?
Our generators feature standard NEMA 5-20R 120V 20A duplex outlets for common power tools. For larger distribution panels or heavy equipment, units include L14-30R 120V/240V 30A twist-lock receptacles. Always match your distribution cables to these specific plug profiles before deploying equipment to the field.
When should I use an inverter generator versus a standard diesel utility generator?
Use inverter generators for sensitive electronics, diagnostic tools, and control systems that require clean, stable power. Standard utility or diesel generators are better suited for high-surge inductive loads like compressors, pumps, and heavy power tools. Inverters also run quieter, making them ideal for indoor finishing work or areas with noise restrictions.
What specifications ensure high bay LED lights can handle dirty or damp environments?
Look for fixtures with aluminum alloy housings and polycarbonate diffusers, which resist impact and corrosion. Ensure the driver supports a wide input voltage range, such as 100-277V AC, to handle utility fluctuations. High bay lights should also offer a high power factor of 0.9 or greater to maximize electrical efficiency on busy circuits.